Jinhua Single is a professinal manufacturer specialized in offering air compressing solutions, our products include L series oil-injected screw air compressor, Off series oil-free screw air compressor, LVSD frequency-converting air compressor, OC series mobile screw air aompressor for abominable environment conditions, HRS energy saving series, ON series for nitrogen and oxygen production, EC series for industrial uses and small piston air compressors, with which nearly all requirements from all walks of life can be met well.
[pdf] Either an electrical problem, or the compressor has tripped on a safety device. Check supply power. Check for errors on display. Check emergency stop is out. Check and reset the overload relay. If it’s a new installation, check the phase sequence. Ambient temperature too high or not enough ventilation.
[pdf] 
We will start our trip through the loop at the same place we will finish: The oil sump. This reservoir is where oil is stored for use in the system. It is usually located in the lower section of a tank-like cylinder, that also houses components used in the air/oil separation process. This is normally a trouble-free component on. .
Oil from the sump flows through small entry passages around the outside of the filter base and is forced through an opening near the closed side of the filter casing, where it. .
This is our first stop in our trip through the system. This valve will direct our lubricant towards its next component based on temperature. Just. .
This component, like the radiator in your car, passes the fluid through tubing encased in a block of baffles, designed to optimize heat transfer. Most air-cooled air compressors have a high capacity fan which will force air through the baffles, and out of the cabinet,. .
Our next stop, assuming our lubricant has reached its operating temperature will be to the oil cooler. As our lubricant has been subjected to extreme friction and bears the brunt of temperature.
[pdf]