If the oil temperature drops below 40°C or exceeds 90°C, the oil’s quality can deteriorate, leading to potential damage and reduced compressor life. When the oil temperature is too low (below 40°C), the oil becomes too viscous, causing increased friction within the compressor.
[pdf] An oil analysis ensures that the oil maintains the right viscosity, additives, and cleanliness levels required for efficient operation. Monitoring the oil’s condition helps prevent excessive wear and tear on critical components such as bearings and rotors.
[pdf] 
We will start our trip through the loop at the same place we will finish: The oil sump. This reservoir is where oil is stored for use in the system. It is usually located in the lower section of a tank-like cylinder, that also houses components used in the air/oil separation process. This is normally a trouble-free component on. .
Oil from the sump flows through small entry passages around the outside of the filter base and is forced through an opening near the closed side of the filter casing, where it. .
This is our first stop in our trip through the system. This valve will direct our lubricant towards its next component based on temperature. Just. .
This component, like the radiator in your car, passes the fluid through tubing encased in a block of baffles, designed to optimize heat transfer. Most air-cooled air compressors have a high capacity fan which will force air through the baffles, and out of the cabinet,. .
Our next stop, assuming our lubricant has reached its operating temperature will be to the oil cooler. As our lubricant has been subjected to extreme friction and bears the brunt of temperature.
[pdf]